Just a quick update:  We've eliminated the "control not found" script error I described above, by eliminating the OnCreateHandler script itself.  Instead of PUSHing the open/collapse buttons via script, we are accomplishing the same by setting appropriate user settings in ECC table ESDUS just prior to opening the ME53N flavor shortlink. In the underlying SAPGUI screen, it is these ESDUS settings that control whether the various sections of the screen (such as Document overview, Help Info, Header section, Item overview, Item Detail etc) will be open or closed when the ME53N screen/flavor loads. Further, the flavor appears to load quicker now compared to the alternative of using OnCreateHandler script to push the appropriate open/collapse/close buttons of the various sections.